K35100 Corrosiveness & Oxidation Stability Apparatus

Test Method
Evaluates the ability of a lubricant to resist oxidation and the formation of corrosive acid compounds by subjecting a sample to accelerated oxidation conditions in a catalytic environment. The sample is maintained at elevated temperature and subjected to a controlled air flow while in the presence of a series of test specimens made of metals commonly found in actual service conditions.
Features and Benefits
- Models for ASTM, Federal and IHC test methods
- Six-sample testing capability
- Solid aluminum block design
- Microprocessor temperature control with digital display and overtemperature protection
K35100 Corrosiveness & Oxidation Stability Apparatus
Constant temperature block baths for corrosivity and oxidation stability determinations on hydraulic oils, aircraft turbine lubricants, transmission fluids and other highly refined oils. Insulated aluminum block provides safe, efficient performance at operating temperatures of up to 750°F (399°C). Microprocessor temperature control has °C/°F switchable digital setpoint and display. Operator and equipment are protected by an overtemperature control circuit which automatically interrupts power to the unit should block temperature exceed a programmed cut-off point. Communications software (RS232, etc.), ramp-to-set and other enhanced features are available as extra cost options. Contact your Koehler representative for information. Air flow is controlled at the specified rate by six individually adjustable flowmeters mounted on a common manifold. Includes inlet valve and outlet fitting for condenser water supply and support rack for glassware.
Specifications
Conforms to the specifications of: ASTM D4636, D5968; FTM 791-5307, FTM 791-5308; IHC BT-10; DIN 51394
Capacity: 6 test cells
Temperature Range:125 to 750°F (51.7 to 399°C)
Temperature Control Stability: ±1°F (±0.5°C)
Air Flow Rate:
ASTM D4636/FTM 791-5307: 10L/h
FTM 791-5308: 3L/h and 5L/h (dual range flowmeters)
IHC BT-10: 3L/h (50mL/min.)
Electrical Requirements
220-240V 50/60Hz, Single Phase, 15.9A
Dimensions lxwxh,in.(cm)
32.5×14.5×4.5 (83x37x105)
Net Weight: 271 lbs (122.9kg)
Shipping Information (without glassware)
Shipping Weight: 375 lbs (170.1kg)
Dimensions: 18.5 Cu. ft.
Ordering Information
| Catalog Number |
Product Description | Model | Electrical Requirements |
| K35100 | Corrosiveness & Oxidation Stability Apparatus | ASTM D4636, D5968 and FTM 791-5307 Model |
220-240V 50/60Hz |
| K35000 | Corrosiveness & Oxidation Stability Apparatus | FTM 791-5308 Model | 220-240V 50/60Hz |
| K35300 | Corrosiveness & Oxidation Stability Apparatus | IHC BT-10 Model | 220-240V 50/60Hz |
Accessories
|
Catalog
Number |
Product Description
|
| Thermometers | |
|
250-000-08F
|
ASTM 8F Thermometer Range: 30 to 760°F |
| 250-000-08C | ASTM 8C Thermometer Range: –2 to +400°C |
| ASTM D4636, D5968, D6594 and FTM 791-5307 | |
| K351-0-1 | Sample Tube |
| K351-0-2 | Sample Tube Head |
| K351-0-3 | Air Tube |
| K351-0-4 | Thermocouple Tube |
| K351-0-5 | Condenser, Allihn Type |
| K351-0-7 | Spacer |
| K351-0-8 | PTFE Adapter |
| K351-0-13 | Oil Sampling Tube (for D5968 and FTM 791-5307) |
| K351-0-14 | Specimen Hanger (for D6594) |
| K293-0-12 | Thermocouple, Type J |
| K29310 |
Digital Thermometer |
| K35090 | Test Panel Assembly Fixture Holds square-shaped metal specimens for tying with cord (for FTM 791-5307 and FTM 791-5308) |
| K35095 | Test Panel Assembly Fixture Holds square-shaped metal specimens for tying with cord (for ASTM D5968) |
| FTM 791-5308 | |
| K350-0-23 | Test Tube |
| K350-0-24 | Air Tube |
| K350-0-25 | Condenser |
| K35090 |
Test Panel Assembly Fixture |
| HC BT-10 | |
| K353-0-1 | Test Cell |
| K353-0-2 | Condenser |
| K353-0-3 | Air Tube |
| K353-0-4 | Ring Rod |
| Washer Shaped Specimens for ASTM D4636 Standard Procedure and for FTM 791-5307 | |
| K35110 | Bronze |
| K35120 | Mild Steel |
| K35130 | Aluminum Alloy |
| K35140 | Magnesium |
| K35150 | Steel M50 |
| K35160 | Silver |
| K35170 | Titanium |
| Square Shaped Specimens for ASTM D4636 Alternate Procedure and for FTM 791-5308 | |
| K35010 | Copper |
| K35020 | Mild Carbon Steel |
| K35030 | Aluminum Alloy |
| K35040 | Magnesium Alloy |
| K35050 | Cadmium Plated Steel |
| K35060 | Silver |
| K35070 | Solid Cadmium (non standard) |
| K35080 | Titanium (non standard) |
| Square Shaped Specimens for ASTM D5968 and D6594 | |
| K35010 | Copper |
| K35011 | Lead |
| K35012 | Tin |
| K35013 | Phosphor Bronze |
| Rectangular Shaped Specimens for IHC BT-10 | |
| K353-0-5 | Aluminum |
| K353-0-6 | Copper |
| K353-0-7 | Steel |
| K353-0-8 | Brass |
| Polishing Materials | |
| 380-150-001 | Silicone Carbide Paper, 150-grit. Pack of 50 sheets. |
| 380-240-001 | Silicone Carbide Paper, 240-grit. Pack of 50 sheets. |
| 380-150-000 | Silicone Carbide Grain, 150-grit. 1 lb package. |
When inquiring about NIST traceable certified thermometers, please refer to the catalog number for the corresponding thermometer and replace the middle three zeros in the catalog number with 004. Example: 251-000-01C ASTM 1C Thermometer would be 251-004-01C ASTM 1C Certified Thermometer.