The first truly portable stand-alone analyzer with a patented rugged FTIR spectrometer for high-speed lubricant oil condition monitoring in full compliance with ASTM, DIN and JOAP methods. With its lightweight build and compact footprint, it is a welcome addition to mobile laboratories to automatically deliver a detailed finger-print of used oil on-site and check for degradation and contamination within seconds.
Fingerprint your oil in seconds

Degradation:
Oxidation, Nitration, Sulphate, Ester breakdown, Phosphate Antiwear Additive and Antioxidant depletion
Contamination:
Soot, Water, Glycol (Antifreeze), Gasoline, Diesel Fuel
Calculated properties (MLR, Cluster analysis):
TAN (Total Acid number), TBN (Total Base Number), Viscosity & Viscosity Index @ 40 °C and 100 °C
all this with a portable analyzer in full compliance with the latest standards such as ASTM E2412, ASTM D7412, D7414, D7415, D7418, D7624, JOAP, DIN 51452, DIN 51453
Portable Stand-Alone Operation
ERASPEC OIL is the first truly portable stand-alone FTIR oil analyzer on the market. It is the ideal solution for on-site measurements, as it provides immediate feedback about the status of the oil also in remote areas, where avoiding equipment breakdown is most critical. With its compact (weighing just 8 kg / 17.6 lb) and rugged design (full metal housing) the ERASPEC OIL brings lab quality results to the field. Its built-in industry PC and the large full color touch screen allow the direct display of the oil spectra as graphic chart. Like this spectra can immediately be analyzed and compared with other spectra, as several thousand spectra can be saved in the internal instrument memory.
Reliable Precision
Lubrication is a vital component of machinery. Early detection of lube oil degradation and engine wear is essential for timely replacement, avoiding unnecessary maintenance while reducing the risk of breakdowns. Infrared (IR) analysis is an inexpensive test that can provide specific information about the chemical condition of the lubricating oil, also allowing inferences about the state of the machine component from which the sample was taken. Due to the speed of IR measurement, the reliability of the results it provides and the large amount of information that can be gained from an IR spectrum it became a routine method for oil analysis laboratories.
With its patented FTIR spectrometer ERASPEC OIL offers highly reliable lubricant oil condition monitoring in full compliance with the latest ASTM, DIN and JOAP methods:
| PARAMETER | STANDARDS | RANGE |
|---|---|---|
| Soot | ASTM E2412 | 0 – 6 m% |
| JOAP, DIN51452 | 0 to > 300 Abs/cm | |
| Oxidation | ASTM E2412 | 0 to > 30 Abs/cm |
| ASTM D7414 | ||
| JOAP, DIN51453 | ||
| Nitration | ASTM E2412 | 0 to > 30 Abs/cm |
| ASTM D7624 | ||
| JOAP, DIN51453 | ||
| Sulfation | ASTM E2412 | 0 to > 30 Abs/cm |
| ASTM D7415 | ||
| JOAP | ||
| Phosphate Antiwear Additives | ASTM E2412 | 0 to > 30 Abs/cm |
| ASTM D7412 | ||
| JOAP | ||
| Antioxidant depletion | to be defined | |
| Water | ASTM E2412 | 0 – 5 m% |
| JOAP | 0 to > 30 Abs/cm | |
| Glycol (Antifreeze) | ASTM E2412 | 0 – 5 m% |
| JOAP | 0 to > 30 Abs/cm | |
| Diesel Fuel | ASTM E2412 | 0 to > 30 Abs/cm |
| JOAP | ||
| Gasoline | ASTM E2412 | 0 to > 30 Abs/cm |
| JOAP | ||
| TAN*) (Total Acid Number) | correlation to ASTM D664 | 0 – 10 mg/g KOH |
| TBN*) (Total Base Number) | correlation to ASTM D2896 | 0 – 10 mg KOH/g |
| Viscosity *) of Engine Oils |
Determination of viscosity class Change in viscosity for used engine oils |
*) These properties are calculated based on a database using Multi-Linear Regression (MLR) and Cluster Analysis. The range and repeatability depend on the database used!
Oil spectra as graphic chart on display
- VIEW SPECTRA - over 3.000 oil spectra can be saved in the internal memory of ERASPEC OIL. They can easily be viewed and analyzed directly on the large color touch screen of ERASPEC OIL without the need of a PC or an external software
- COMPARE SPECTRA - up to 4 oil spectra can be viewed upon each other for convenient comparison
- ANALYZE SPECTRA - single peaks can be analyzed in detail using the zoom function
PERFORMANCE YOU CAN RELY ON

FAST & EASY OPERATION
All eralytics analyzers use an intuitive menu structure that is easy to navigate. Samples need no prior preparation and measurements are done fully automated.
The results are displayed immediately after the test on the large and user-friendly color touch screen. The internal memory holds thousands of measurement results. For convenience, data can be directly saved to USB memory sticks for further processing or a thorough analysis. The data format is compatible with most PC spreadsheets, such as Microsoft© Excel. Customized print-out designs are available for easy direct printing.
Oil testing in three easy steps with the ERASPEC OIL
- Select/enter the Sample ID and the Operator
- Put the inlet tube into the sample
- Press RUN to start the fully automated measurement

ERASOFT RCS – REMOTE CONTROL PC SOFTWARE
The RCS software is the ideal tool for operating one or more ERASPEC OIL instruments via a PC. As an alternative to LIMS, it allows for convenient data transfer and fast analysis of results and spectra
- MULTI-INSTRUMENT NETWORKING
- CONVENIENT ANALYSIS AND COMPARISON OF OIL SPECTRA
- FAST & EASY DATA TRANSFER (RESULTS, SPECTRA, SETTINGS, LIBRARIES, ETC.)
- SOFTWARE UP-GRADE
- BACKUP/RESTORE THE CONFIGURATION AND UNIT PARAMETERS

COMPACT STAND-ALONE ANALYZER
All eralytics instruments are compact stand-alone analyzers with a built-in industrial PC. They represent the latest in technology, designed for longterm, maintenance-free operation. Of course, all eralytics analyzers use cutting-edge industry technology and provide universal data transfer options. Ethernet and USB interfaces allow advanced data management and connectivity to PCs, modern printers, keyboards, PC-mice, barcode readers, or other external equipment.
DIRECT LIMS COMMUNICATION
A direct out-of-the-box connection to LIMS (Laboratory Information Management System) is established with a standard Ethernet cable.No extra software or PC is needed.
TRUE PORTABILITY
The small footprint of the eralytics instruments makes them the first choice for use in the lab and on-site. Lightweight and built with an integrated carrying handle they are ideally suited for mobile applications.
LARGE RESULTS MEMORY
Data are stored safely in the large results memory, which holds many thousand records. Six user levels and a state-of-the-art password technology protect your test result data from accidental deletion.
SERVICE AND REMOTE CONTROL OVER THE INTERNET
At the push of a button, firmware and software updates can be downloaded from the internet. The internet connection also allows to remotely control eralytics analyzers or to perform standard service activities.
| TECHNICAL SPECIFICATIONS | |
| Available test methods | ASTM E2412, ASTM D7412, D7414, D7415, D7418, D7624, JOAP, DIN 51452, DIN 51453 excellent correlation to ASTM D445, D664, D2270 and D2896 |
| Spectrometer type | MID-FTIR interferometer (patented laser and temperature controlled design) 16384 data points; scanning range: 450 to 7000 cm-1 |
| Calibration | Factory calibrated with a matrix of international oils |
| Warm-up time | 30 seconds |
| Measuring time | 60 – 120 seconds |
| Sample introduction | Directly from the sample container by an integrated pump |
| Cleaning | Automatic rinsing with next sample or solvent |
| Filter | Integrated 80 µ metal filter |
| Sample volume | 10 ml |
| Display | 7’’ four-color touch screen |
| Communication languages | English, German, French, Spanish, Portuguese, Russian, Chinese, etc. |
| Interfaces | Built-in PC with Ethernet, USB and RS232 interfaces; direct LIMS connectivity and output to printer or PC |
| Remote control | Remote service capability via Ethernet interface |
| Result database | ? 3,000 detailed test reports and spectra stored in the internal memory |
| Operators | More than 100 operator names memorized |
| Alarm tracking | All messages are stored in the database with the result |
| Power Requirements | Auto switching 85-264 V AC, 47-63 Hz, 70 W (multi-voltage power supply) Field application: 12V/7A DC (vehicle battery) |
| Dimensions / Weight | 22 x 32 x 28 cm (8.7 x 12.6 x 11 in) / 8 kg (17.6 lb) |
| Accessories | ERASOFT RCS – PC software for multi instrument networking, result & spectra download, view and analysis of spectra, software up-date, etc. |
| Carrying case for safe transport and storage | |
| DC-adaptor for +12 V vehicle battery operation | |
| Printer (USB Laser printer, parallel DeskJet or Dot Matrix) | |
Due to continuing product development, specifications are subject to change. All eralytics products are manufactured under ISO 9001 regulations and are CE compliant.