K8610-1003 Ethanol Purity & Methanol Content by Gas Chromatograph

K8610-1003 Ethanol Purity & Methanol Content by Gas Chromatograph

  • Highly-configurable, low-cost, compact & portable
  • Ambient-to-400C temperature-programmable column oven
  • Electronic Pressure Control (EPC) of all GC system gases, including carrier gas
  • LED “at-a-glance” display of all temp, pressure, & voltage-controlled zones
    Includes
  • Flame Ionization Detector (FID)
  • Single-channel USB 2.0-compliant data acquisition hardware
  • PeakSimple data acquisition & control software for WinXP on IBM PC
  • 6′ USB 2.0 Cable (A to B)
  • GC Accessory Kit
  • Reusable shipping crate for safe portability
  • Operation & Service Manuals
  • Free software updates

Test Method

ASTM D5501 covers the determination of the ethanol content of denatured fuel ethanol by Gas Chromatography. Ethanol is determined from 93 to 97 mass % and methanol is determined from 0.1 to 0.6 mass %. ASTM D5501 does identify and quantify methanol but does not purport to identify all individual components that make up the denaturant. This test method provides a method of determining the percentage of ethanol (purity) of the fuel ethanol that is blended into gasoline.

Gas Chromatograph

The Gas Chromatography 8610 serial chassis can be configured to perform and satisfy all of the requirements of either ASTM D5501 or EN 14110 for Ethanol purity and Methanol content. Analysis takes about 25 minutes and is simple enough for an untrained operator to perform in the lab or in the field. The included PeakSimple Data System displays the calibrated results directly without off-line calculations.

Specifications

Conforms to the specifications of: ASTM D5501, EN 14110

Dimensions lxwxh,in.(cm)

19 x 14.5 x 12.5 (48.5 x 36.75 x 30.5)
Net Weight: 37 lbs (16.8 kg)

Shipping Information

Shipping Weight: 52.5 lbs (23.9 kg)
Dimensions: 4.9 Cu. ft.

Ordering Information

Catalog
Number
Product Description
K8610-1003 Gas Chromatograph, 8610C serial chassis,
110V 60Hz
K8690-0010 Required Configuration for D5501
Flame Ionization Detector (FID)
K8690-0034 Heated Split-Splitless Injector Upgrade
K8600-WBCX MXT-1 Capillary Column (105M x0.25mm ID, 0.5 DB-1)
K8690-0010 Required Configuration for EN 14110
Flame Ionization Detector (FID)
K8690-0034 Heated Split-Splitless Injection Port Upgrade
K8690-0045 Heated Static Headspace Injector Upgrade
K8600-WBWB MXT-WAX Capillary Column (30M x 0.53mm ID x 0.5 µ)

Accessories

Catalog
Number
Product Description
K8680-0350
Optional Hydrogen Generator
K8690-0070
Optional built-in air compressor
K8600-C590 Gas Line Installation Kit for Air Cylinder (FID)
K8600-C350 Gas Line Installation Kit for Hydrogen Cylinder (FID)
K8600-C580 Gas Line Installation Kit for Helium Cylinder (carrier gas)
  Add the optional gas generators above for cylinder free operation