K45950 Cold Filter Plugging Point Bath

Test Method
Determines the low temperature flow characteristics of automotive diesel fuels and gas oils, including samples with flow improving additives, by measuring the temperature at which the sample ceases to flow through a wire mesh filter under standard test conditions. Complete test consists of Cold Filter Plugging Point Apparatus, Vacuum System and Cooling Bath.
Features and Benefits
- Conforms to ASTM D6371, IP 309 and DIN 51428 specifications.
- Choice of mechanically refrigerated or dry ice cooled bath.
K45950 Cold Filter Plugging Point Bath
Cold Filter Plugging Point Apparatus–Includes Pyrex™ test jar with graduation, brass jacket with plastic support ring, plastic stopper, plastic insulating ring and spacer, pipette and brass filter unit with stainless steel fine wire mesh screen.
Vacuum System–Connects to Cold Filter Plugging Point Apparatus to draw sample through filter screen. Consists of U-tube Manometer (without mercury), three-way stopcock, air vent tube, cork stopper with elbows, and large glass bottle. Vacuum pump is not included.
Cooling Baths–Choice of mechanically refrigerated or dry-ice cooled baths. Mechanically refrigerated model utilizes a cascade hermetic cooling system to attain temperatures as low as –90°F (–68°C). Cold Filter Plugging Point Apparatus inserts in composition top plate of bath. Insulated stainless steel tank and polished stainless steel cabinet.
Dry-ice model includes insulated copper interior and steel exterior with corrosion resistant polyurethane enamel finish. Composition top plate suspends Cold Filter Plugging Point Apparatus in freezing mixture at the required depth. Handles on exterior permit easy emptying of freezing mixture. Supplied with thermometer holder.
Specifications
Conforms to the specifications of: ASTM D6371; IP 309; DIN 51428
Electrical Requirements
Mechanically Refrigerated Baths
115V 60Hz, Single Phase, 6A
220-240V 50Hz, Single Phase, 3A
Dimensions in.(cm):
Refrigerated Model (Ixwxh):
35x26x31 (89x66x78.75)
Net Weight: 259 lbs (117.75kg)
Dry-Ice Model (dia.xh):
12×12 (30×30)
*Cooling Bath
Shipping Information
Shipping Weight:
Refrigerated Model: 373 lbs (169.5kg)
Dry-Ice Model: 19 lbs (8.6kg)
Dimensions:
Refrigerated Model: 23.75 Cu. ft.
Dry-Ice Model: 3 Cu. ft.
Ordering Information
|
Catalog
Number |
Product Description
|
Electrical Requirements
|
|
K45900
|
Cold Filter Plugging Point Apparatus | |
|
K45920
|
Vacuum System | |
|
K45950
|
Mechanically Refrigerated Cold Filter Plugging Point Cooling Bath |
115V 60Hz |
|
K45995
|
Mechanically Refrigerated Cold Filter Plugging Point Cooling Bath |
220-240V 50Hz |
|
K45910
|
Cooling Bath, Dry Ice Model |
Accessories
|
Catalog
Number |
Product Description
|
|
250-000-05C
|
ASTM 5C Thermometer Range: –38 to +50°C |
|
250-000-06C
|
ASTM 6C Thermometer Range: –80 to +20°C. |
When inquiring about NIST traceable certified thermometers, please refer to the catalog number for the corresponding thermometer and replace the middle three zeros in the catalog number with 004. Example: 251-000-01C ASTM 1C Thermometer would be 251-004-01C ASTM 1C Certified Thermometer.